Cat VR3 and Cat VR4 (Now obsolete and replaced by VR6) Leroy Somer 202-8634 or 2028634; Basler AVC63-12B1.KATO Engineering Model K65-12B (Part # 810-35334-00).WARNING! The VR6-A can replace KATO model K65-12B, BUT - the KATO only senses 120V instead of 200-240V like the VR6-A, so the installer will need to be sure the VR6-A is wired to accept.
- Shop for a Caterpillar AVR with General Power. Browse our large inventory and industry-leading lead times that can be weeks quicker than the competition. Call Us: 1-888-819-5646.
- The best aftermarker replacement for a CAT VR3 is a Basler AVC63-12, they offer several different sensing voltage ranges. Both the VR3 and the VR6 (and the Basler and Kato versions) have a power input burden of about 1100VA, and the sensing burden is less than 1 VA.
- Regulator for Cat VR6, Basler AVC63-12B1, CAT 309-1019 AVR - Quality After-market AVR Replaces: Caterpillar model VR6 (CAT 309-1019 or kit # 365-2076) Cat VR3 and Cat VR4 (Now obsolete and replaced by VR6) Leroy Somer 202-8634 or 2028634 Basler AVC63-12B1.KATO Engineering Model K65-12B (Part # 810-35334-00).WARNING!

Usage:
3412C4BZ| Illustration 1 | g00779092 |
| Manual Voltage Control Panel (Option) (1) Switch (OFF, AUTO, and MAN positions) (2) Voltage control potentiometer (3) Fuse | |
Cat Vr6 Voltage Regulator Manual
The manual voltage control is an option. The manual voltage control can be used to control the generator voltage when there is a failure in the generator regulator assembly. The manual voltage control will manually control the current flow to the exciter stator. The manual voltage control panel has a switch (1) and a voltage control potentiometer (2) for the manual operating mode. The switch (1) is used to make the selection between the following positions: AUTO, MAN and OFF.
In the AUTO position, the VR6 voltage regulator controls the generator voltage.
| Illustration 2 | g01021519 |
The Cat VR6 presents an electrical shock/electrocution hazard. This hazard will cause serious injury or death. Service by trained personnel only. The terminals and heat sinks are live at hazardous voltages when power is applied and for up to 8 minutes after power is removed. |
In the OFF position, the generator output voltage will go to near zero.
In the MAN position, the generator output voltage is controlled by the voltage control potentiometer (2).
Cat Vr6 Voltage Regulator Manual Wiring
Note: /all-in-one-runtimes-32-bit.html. The manual voltage control panel must not be installed in a location that is subject to engine vibrations or to outside weather.
Cat Vr6 Voltage Regulator Manual Diagram
Note: When the manual voltage control is operating in the manual mode, power MUST be removed from the VR6. Refer to the Testing and Adjusting, 'Wiring Diagrams' for proper connections.
Cat Vr6 Voltage Regulator Manual Briggs And Stratton

Cat Vr6 Voltage Regulator Manual Fuse
Note: Do not rapidly switch the 'Manual Voltage Control' (MVC) from 'Manual' to 'Auto' or from 'Auto' to 'Manual'. The switch must stop or pause at the 'OFF' position momentarily. Bike mayhem mod apk download for android. If the position of the switch is changed too rapidly, then the VR6 will shut down due to the 'Over Excitation' protection function.